Quick start guides
AI Blood Smear Analysis quick start guide
AI Dermatology Diagnostics Quick Start Guide (PDF)
AI Equine Fecal Egg Count Analysis Quick Start Guide (PDF)
AI Fecal Analysis Quick Start Guide (PDF)
AI Urine Sediment Analysis Quick Start Guide
Digital Cytology Quick Start Guide (PDF)
Vetscan Imagyst product guides
AI Blood Smear Analysis
AI Blood Smear Analysis slide preparation
Scanning an AI Blood Smear Analysis test
Reviewing AI Blood Smear Analysis results
AI Dermatology Diagnostics
AI Dermatology infectious agent semi-quantitative category overview (PDF)
AI Dermatology left and right ears sample preparation guide (PDF)
AI Dermatology Diagnostics sample preparation
Scanning an AI Dermatology Diagnostics slide
Reviewing AI Dermatology Diagnostics results
AI Equine Fecal Egg Count Analysis
AI Equine Faecal Worm Egg Count (FEC) Analysis slide preparation
Reviewing AI Equine Faecal Worm Egg Count results
AI Fecal Analysis
AI Faecal Analysis slide preparation
AI Faecal Analysis coverslip placement
Scanning an AI Faecal Analysis slide
Reviewing AI Faecal Analysis results
AI Urine Sediment Analysis
AI Urine Sediment complete urine sediment analysis point of care (PDF)
AI Urine Sediment hospital resource guide (PDF)
AI Urine Sediment medical whitepaper (PDF)
AI Urine Sediment Analysis dilution procedure (PDF)
AI Urine Sediment Analysis slide preparation
Scanning an AI Urine Sediment Analysis test
Reviewing AI Urine Sediment Analysis results
Digital Cytology
Body cavity (pericardial) (PDF)
Body cavity (pleural, peritoneal) (PDF)
CSF (cerebrospinal fluid) (PDF)
Synovial/joint (PDF)
Washes (PDF)
Adding a cytology test
Prepare the Digital Cytology slide
Digital Cytology order entry
Scanning a Digital Cytology slide
Fluid site card
Lesion site card
Reviewing Digital Cytology results
User Guide
Vetscan Imagyst overview
Company information
Gallery view
Adjust colour
Assessment Drawer
Carousel view
Gallery view
Gallery view actions panel
Gallery view features
Gallery view results panel
Grundium Ocus scanner overview
Grundium scanner troubleshooting guide
Routine scanner cleaning (PDF)
Scan area masks for Grundium scanners
Signing in, signing out and session security
Email (username)
Change password
Forgotten email (username)
Forgotten password
Adding a temporary field of view (FOV) box for AI Urine Sediment Analysis
Adding, editing and deleting measurements
Editing an image capture
Exemplars gallery
Slide view
Slide view counts panel
Slide view features
Toggle measurements
Video guides
AI Blood Smear Analysis demonstration
AI Blood Smear Analysis do's and don'ts
AI Blood Smear Enhanced Workflow and Reporting
AI Blood Smear Analysis using new methylene blue (NMB) stain
Faecal check list
How to: run a fecal test
Faecal step 1: collect faecal matter
Fecal step 2: prepare the fecal sample
Fecal step 3: add the sample to a slide
Fecal step 4: place a coverslip on the slide
Fecal step 5: initiate the test
Digital Cytology demo
How to: blood smear
How to: coverslip and immersion oil
How to: dos and don'ts
How to: ear cytology
How to: fecal cytology
How to: fine needle aspiration
How to: fine needle biopsy
How to: line smear
How to: skin lesions/scrapings
How to: stain a slide
How to: urine sediment
How to: using the Imagyst application
- All Categories
- Vetscan Imagyst product guides
- Digital Cytology
- Digital Cytology order entry
Digital Cytology order entry
Updated
by Shannon Mitchell
When a new test is created from the Worklist page, and the Digital Cytology test type is selected, the Digital Cytology order entry page appears with sections to enter details about the patient and test, as well as add site card descriptions. For more information, view Adding a Digital Cytology test.
To view the Digital Cytology order entry page:
- Click Main Menu (
- Click the Worklist link.
- Click Add Test (
- Click the dropdown arrow to select the Digital Cytology test type.
Digital Cytology test order sections
A Digital Cytology test order has sections to ensure the Virtual Reference Laboratory (VRL) has enough information to diagnose the animal. Some sections feature menu selections, while others need more description. The patient history, which includes species, breed, age, sex, where to submit the test and clinical history, auto-saves whenever a change occurs.
Section | Description |
Species | A species list, including canine, equine and feline, is available, or you can add a new species. You can select the species when you create a new test, but you also have the option to edit it later if needed. Note: If a newly entered species is created, it will be remembered in the system for future use, and you can also choose to remove it. |
Breed | An optional menu of the different breeds of the chosen species. A new breed can also be entered if a newly entered species is created. |
Age | A menu of ages ranging from one month to 20+ years. |
Sex | A menu of the sex and reproductive status of the animal. |
Submit test to | A menu of the labs to which you can send your tests. Note: If the priority tests feature is enabled, two priority options are available for selection:
|
Clinical history | A section with unlimited characters describes an animal's clinical history. It is recommended that the history be kept brief, as this is best for the technicians at the reference lab. |
Sample details
The sample details include site cards, which appear above the sidebar in the slide view. Site cards display information for the test entered during test creation, including details like USG, RBC count, or colours. The site cards are visible in the sidebar for all AI tests.
Fluid site | A site card used to describe a test prepared from a fluid sample. For more information, view Fluid site card. |
Lesion site | A site card used to describe a test prepared from a lesion sample. For more information, view Lesion site card. |
Order entry features
Feature | Description |
Attach files | Click to attach up to three files to a test. These files can be JPG/JPEG and PDF. |
Close | Click to close the test order without submitting it. Vetscan Imagyst auto-saves the patient history to save the information within the history. |
Submit order | Click to submit the order. Once submitted and assigned to a technician at the reference lab, the test cannot be edited. |
Attach files
It is possible to attach up to three files (in JPG/JPEG or PDF format) to a test.
To attach a file to a test:
- Click Attach files at the lower right of the page.
- Drag and drop a file into the upload box. Or, click Choose file to browse your computer and locate a file to upload.
- Click the file name under the documents section to preview it.
- Click the Close button. The Attach files button will display a number indicating how many files have been uploaded.
Important: To delete an attached file, click Attach files and then click the (X) next to the file you want to delete.
Closing a test