Quick start guides
AI Blood Smear Analysis quick start guide
AI Dermatology Diagnostics Quick Start Guide (PDF)
AI Equine Fecal Egg Count Analysis Quick Start Guide (PDF)
AI Fecal Analysis Quick Start Guide (PDF)
AI Urine Sediment Analysis Quick Start Guide
Digital Cytology Quick Start Guide (PDF)
Vetscan Imagyst product guides
AI Blood Smear Analysis
AI Blood Smear Analysis slide preparation
Scanning an AI Blood Smear Analysis test
Reviewing AI Blood Smear Analysis results
AI Dermatology Diagnostics
AI Dermatology Diagnostics sample preparation
Scanning an AI Dermatology Diagnostics slide
Reviewing AI Dermatology Diagnostics results
AI Equine Fecal Egg Count Analysis
AI Equine Faecal Worm Egg Count (FEC) Analysis slide preparation
Reviewing AI Equine Faecal Worm Egg Count results
AI Fecal Analysis
AI Faecal Analysis slide preparation
AI Faecal Analysis coverslip placement
Scanning an AI Faecal Analysis slide
Reviewing AI Faecal Analysis results
AI Urine Sediment Analysis
AI Urine Sediment Analysis slide preparation
Scanning an AI Urine Sediment Analysis test
Reviewing AI Urine Sediment Analysis results
Digital Cytology
User Guide
Vetscan Imagyst overview
Company information
Gallery view
Adjust colour
Assessment Drawer
Carousel view
Gallery view
Gallery view actions panel
Gallery view features
Gallery view results panel
Grundium Ocus scanner overview
Grundium scanner troubleshooting guide
Routine scanner cleaning (PDF)
Scan area masks for Grundium scanners
Signing in, signing out and session security
Email (username)
Change password
Forgotten email (username)
Forgotten password
Adding a temporary field of view (FOV) box for AI Urine Sediment Analysis
Adding, editing and deleting measurements
Editing an image capture
Exemplars gallery
Slide view
Slide view counts panel
Slide view features
Toggle measurements
Tips
AI Dermatology left and right ears sample preparation guide (PDF)
AI Dermatology infectious agent semi-quantitative category overview (PDF)
AI Urine Sediment complete urine sediment analysis point of care (PDF)
AI Urine Sediment hospital resource guide (PDF)
AI Urine Sediment medical whitepaper (PDF)
Body cavity (pericardial) (PDF)
Body cavity (pleural, peritoneal) (PDF)
CSF (cerebrospinal fluid) (PDF)
Synovial/joint (PDF)
Washes (PDF)
Blood smear (PDF)
The basics (staining and submission) (PDF)
Improving suspected lipoma cytology samples (PDF)
Other sample types (PDF)
Tissue cytology (fine needle biopsy/aspiration) (PDF)
Video guides
AI Blood Smear Analysis demonstration
AI Blood Smear Analysis do's and don'ts
AI Blood Smear Enhanced Workflow and Reporting
AI Blood Smear Analysis using new methylene blue (NMB) stain
Faecal check list
How to: run a fecal test
Faecal step 1: collect faecal matter
Fecal step 2: prepare the fecal sample
Fecal step 3: add the sample to a slide
Fecal step 4: place a coverslip on the slide
Fecal step 5: initiate the test
Digital Cytology demo
How to: blood smear
How to: coverslip and immersion oil
How to: dos and don'ts
How to: ear cytology
How to: fecal cytology
How to: fine needle aspiration
How to: fine needle biopsy
How to: line smear
How to: skin lesions/scrapings
How to: stain a slide
How to: urine sediment
How to: using the Imagyst application
- All Categories
- User Guide
- Company information
- Adding, editing and deleting company information
Adding, editing and deleting company information
Updated
by Shannon Mitchell
Add, edit and delete elements within the Company information, branding, scans filters, worklist filters, API client, haematology settings and object border settings sections.
To access the Company information page:
- Click Main Menu (
).
- Click the Company information link.
Edit company information
To edit information in the Company information section:
- Click on the name, address, contact name, contact surname, email, phone, or objects displayed per classification to edit the current information.
Note: The number entered for objects displayed per classification becomes the default number of images/objects displayed for each classification on the Gallery view page. The suggested default number is 50. - Click the drop-down arrow and choose a new country, time zone, or language.
Note: The selected language becomes the default language for any new user added to the company. - Click Save.
Important: Navigating away from the page without clicking Save cancels any changes you may have made.
Adding or editing a company logo
To add or edit a company logo:
- From the Company information page, scroll down to the Branding section.
- Click Edit (
).
Note: You follow the same steps, whether adding a logo for the first time or updating an existing one. - Click the Upload link.
- When the file selection dialogue opens, select a file and click Open.
Important: A logo cannot be larger than 48px high and 220px wide, with a maximum file size of 2MB. You must use the .png, .jpg, .jpeg, .gif, .bmp, or .svg file formats. - Click Done.
Deleting a company logo
To delete a company logo:
- From the Company information page, scroll down to the Branding section.
- Click Edit (
).
- Click the Remove link.
- When the Remove logo confirmation dialogue opens, click Yes.
Important: Clicking anywhere outside the Remove logo confirmation dialog or clicking on No exits the dialog without deleting the logo. - Click Done.
Adding or editing FUSE integration information
- From the Company information page, scroll down to the FUSE integration section.
- Click the Create FUSE ID link. The system will automatically create a FUSE ID with the option to copy it.
Note: Only specific roles can access this feature.
Add a VRL ID configuration
- Click Main Menu (
).
- Click on the company for which you want to enter the VRL ID.
- Click Edit (
).
- Scroll down to the VRL configuration section.
- Enter the ID number and name of the reference laboratory you want to add.
Important: A blank VRL configuration, by default, sends all tests to the Zoetis Virtual Lab (ID: 485). - Choose which lab you want to make your preferred lab.
- Click Save.
Important: If you exit the page without saving the changes, the VRL override ID will not be set.
Adding an object border setting
- Scroll down to the Object border settings section from the Company information page.
- Click Add border default.
- When a new Border default listing opens, select an Object type from the dropdown menu, a border colour from the colour selector, and enter a width.
- Click Save.
Important: Navigating away from the page without clicking Save cancels any changes you may have made.
Editing an object border setting
- Scroll down to the Object border settings section from the Company information page.
- Click on the Object type dropdown to select a different object type.
- Click on the colour square to choose a different colour.
- Click on the Border width field to change the border width value.
- Click Save.
Important: Navigating away from the page without clicking Save cancels any changes you may have made.
Deleting an object border setting
- Scroll down to the Object border settings section from the Company information page.
- Click Delete (
) to set the selected object border.
Important: Deleting the Object border settings does not have a confirmation dialog. When you click Delete, the setting is immediately removed.